| Integrated Glass Chip•Institute of Microchemical Technology Co., Ltd. | |||||||||||
|
|||||||||||
![]() |
|||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product code | Channel dimension | Function |
|---|---|---|
| ICC-SY05 | width : 100um depth : 40um length after meeting the flows : 40mm |
Mixing , Reaction , laminar flow |
| ICC-SY10 | width : 100um depth : 40um length after meeting the flows : 80mm |
Mixing , Reaction , laminar flow |
| ICC-SY15 | width : 100um depth : 40um length after meeting the flows : 120mm |
Mixing , Reaction , laminar flow |
| ICC-SY200 | width : 100um depth : 40um length after meeting the flows : 200mm |
Mixing , Reaction , laminar flow |
| ICC-SY500 | width : 100um depth : 40um length after meeting the flows : 500mm |
Mixing , Reaction , laminar flow |
| ICC-SY500MI | width : 100um depth : 40um length after meeting the flows : 500mm High-mixture use |
Mixing , Reaction , laminar flow |
| ICC-DY05 | width : 100um depth : 40um length after meeting the flows : 20mm |
Solvent extraction, Separation, Laminar flow, Concentration |
| ICC-DY10 | width : 100um depth : 40um length after meeting the flows : 80mm |
Solvent extraction, Separation, Laminar flow, Concentration |
| ICC-DY15 | width : 100um depth : 40um length after meeting the flows : 120mm |
Solvent extraction, Separation, Laminar flow, Concentration |
| ICC-DY200 | width : 100um depth : 40um length after meeting the flows : 200mm |
Solvent extraction, Separation, Laminar flow, Concentration |
| ICC-DY05G | width : Laminar flow area 160um /others 100um depth : 40um length after meeting the flows : 20mm "Guide" structure with 36-38um height |
Solvent extraction, Separation, Laminar flow, Concentration |
| ICC-DY10G | width : Laminar flow area 160um /others 100um depth : 40um length after meeting the flows : 80mm "Guide" structure with 36-38um height |
Solvent extraction, Separation, Laminar flow, Concentration |
| ICC-DY15G | width : Laminar flow area 160um /others 100um depth : 40um length after meeting the flows : 120mm "Guide" structure with 36-38um height |
Solvent extraction, Separation, Laminar flow, Concentration |
| ICC-DI 05 | width : 100um depth : 40um length : 60mm |
Molecular transportation |
| ICC-2CSK | width : 210um depth : 100um "Dam" structure with 10-20um opening, 2 "Dam" lines . |
Immunoassay on Latex beads |
| ICC-KG01 | width : 100um depth : 40um length after meeting the flows : 276mm before the 3rd flow is joined, 124mm after that. |
Combination, Separation, Solvent extraction |
| ICC-PT100 | width of "pool" : 10 × 5 mm depth of "pool" : 100um Cover glass and Slide glass aren't laminated. |
Detector cell of microscopic observation and fractography |
| ICC-DE05 | width : 50um depth : 20um |
Electrophoresis |
Besides the channels for the micro fluidics, each chip has the channels to eliminate gas between glass plates when they are laminated. They have no bad effects for your experiments. The channel dimension may have about 10% of variation. The delivery is normally 4-7days.
·Please see the details below about "Guide" and "Dam" structures.
| Custom-made chip | ||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||